Digital multimeter unit UT-70B measures DC and AC current and voltage, resistance, capacitance, frequency, temperature, continuity and diode test. For lightweight work a multimeter in the device is a function of data hold.
Technical characteristics of the DMM Unit UT70B:
Display |
3999 counts LCD display with backlight, 62 53 mm x |
Constant voltage (DC) |
Range |
400 mV / 4 V / 40 V / 400 V / 1000 V |
Error |
±(0,8%+1) |
An alternating voltage (AC) |
Range |
4 V / 40 V / 400 V / 750 V |
Error |
±(1%+5) |
Direct current (DC) |
Range |
400 µa / 4000 µa / 40 A / 400 mA / 10 A |
Error |
±(1%+2) |
Alternating current (AC) |
Range |
400 µa / 4000 µa / 40 A / 400 mA / 10 A |
Error |
±(1,5%+5) |
Resistance |
Range |
400 Ohm / 4 kOhm / 40 kOhm / 400 kOhm / 4 MOhm / 40 MOhm |
Error |
±(1%+2) |
Capacity |
Range |
4 nF / 40 nF / 400 nF / 4 µf / 40 µf / 400 µf / 4 MF / 40 MF |
Error |
±(4%+3) |
Frequency |
Range |
4 kHz / 40 kHz / 400 kHz / 4 MHz / 40 MHz / 400 MHz |
Error |
±(0,1%+3) |
Temperature ?C |
Range |
-401000 |
Error |
±(1%+3); |
Temperature ?F |
Range |
-401832 |
Error |
±(1%+4); |
Food |
battery 9V: 6F22 |
Dimensions (h x W x d), mm |
195 x 90 x 40 |
Weight, g |
560 |
The functionality of a digital multimeter unit UTM 170B (UT70B):
- AC and DC current
- AC / DC voltage
- Resistance
- Capacity
- Frequency
- Temperature (?C and ?F)
- Continuity test (with buzzer)
- Diode test
- Automatic range selection
- The function "Data Hold" (hold data)
- Sleep
- Overload protection up to 10 A
- The maximum/minimum values "Max/Min"
- The relative display mode
- Indicator low battery
Equipment digital multimeter unit UTM 170B (UT70B):
- Multimeter unit UTM 170B
- Probes
- Thermocouple
- RS232C cable
- AT
- Battery
- User manual